VARMATIC LIGHTMASTER
Technical Specification
The idea behind the Varmatic Lightmaster is simplicity
itself. The amount of power actually required to supply most forms
of lighting is less than what is actually drawn by the lights themselves.
The Varmatic Lightmaster is designed to bridge this gap, and deliver
significant energy cost savings on your lighting.
The Varmatic Lightmaster has been developed after extensive research
by our by our R&D department and incorporates specially designed
electronic and electrical components which provide the optimum
saving possible.
| VOLTAGE: |
240V (SPN) - Single Phase and 415V
(TPN) - Three Phase |
| TEMPERATURE: |
Designed for typical switchroom ambients (0ºC
- 35ºC)
The units are either fitted with louvres or forced air ventilation |
| KEY FEATURES: |
Automatic Bypass Facility
Protected Inputs
Status Indication
Key Operable Selector Switching
Key Operable Doors
Isolating Device |
| OPTIONS: |
We can offer a number of options to enhance
our standard units:
• Jointing kits (for installations)
• Omission of multi-meter (kWh) system on the three phase unit
• Remote by-pass switching override
• Remote switching of Varmatic Lightmaster
• Option of MCCB protection instead of fused isolator
• Outgoing protected ways
• Time clock with automatic switching
• Special look enclosure (and paint specification) design
• Distribution board included with Varmatic Lightmaster
• Sectionalised contactor switching of load
• Various auxiliary controls: timers, proximity detection, etc
• Special input (i.e. 110V ac, etc)
• On-site supervision or installation available |
| SERVICE: |
Detailed recommendations after "onsite" surveys
After sales back-up and service
Installation service available |
PRINCIPLES BEHIND OPERATION OF THE VARMATIC
LIGHTMASTER
The theory behind the system is that lighting takes more power
than it actually needs. The Varmatic Lightmaster uses
electronic devices in order to monitor and automatically adjust
this power, and provide a stable and optimum sustainable output.
During initial tests, it was found that in common types of lighting
the actual kilowatt input to the whole system could be significantly
reduced, whilst still maintaining high quality light output. A
combination of the following factors were thought to be responsible
for this phenomenon:
- Ballast control of lighting circuits
- Increase the light output per watt of power input
- Reduction in wasted losses in the ballast circuit
- Efficiency against power input fluctuations / power efficiency
improvements of the "regulator circuit"
- Manufacturing tolerances (lighting)
- Unique monitoring and adjustment control of our "regulator
circuit" within the Varmatic Lightmaster
- The basic principle behind ballasts is that they are non-linear
in response to varying power inputs. What was found was that
upon initial stabilisation of the ballast itself, that a controlled
reduction in power will directly result in a reduction in ballast
losses / watts, whilst still maintaining lamp stability. It is
these reductions in losses that provide the majority of the savings.
All of this is achieved without the need to either alter or interfere
with the sine wave of the ac supply (as the sinusoidal waveform
of the lighting load is unaffected). This is why we also state
that our system is harmonically neutral and no "chopping" of
the waveform takes place.
Below are some additional points of interest about the
Varmatic Lightmaster:
- Extends lamp life
- Reduces loading on cables and switchgear - leading to reduced
chance of damage or fire as a result of overheating
- Fail safe protected
- Transparent to user
- All energy saving claims can be substantiated
- Makes best use of potential energy savings of existing lighting
circuits - although it is true to say that the newer style of
lighting yields better results
- Continuity of load provided by closed loop technology and
bypass switching
- Long life expectancy of product
- Wide range of lighting applications - from car parks, shopping
malls, factories to warehouses - the Varmatic Lightmaster can
be used in all
- Optional extras can be provided - such as distribution circuits,
timing or other controls; special metering or indication; specially
designed units for specialised applications
- Installation kits can be provided for ease of fitting
- Light output changes whilst using the Varmatic Lightmaster
are imperceptible to the human eye
- During its short life (only launched in February 2001) the
Varmatic Lightmaster has attracted huge interest from a wide
range of companies in the market place such as local government,
heavy industry, retail, and leisure outlets.
- Typical paybacks of between 12-24 months - making this product
one of the wisest investments your company will ever make
- No need to re-wire your lighting circuits, as all interconnections
are done at the distribution boards
- On board metering (optional on the single phase units) providing
a method of ongoing savings
- Built to latest British and European standards.

SINGLE-PHASE
240V SPN
|
| PART No. |
DIM A (mm) |
DIM B (mm) |
DIM C (mm) |
WEIGHT (kgs) |
| LM005/1 |
600 |
400 |
250 |
23 |
| LM010/1 |
600 |
600 |
300 |
37 |
| LM015/1 |
600 |
600 |
300 |
45 |
| LM020/1 |
600 |
600 |
300 |
52 |
| LM030/1 |
1000 |
800 |
400 |
67 |
| LM040/1 |
1000 |
800 |
400 |
99 |
| LM050/1 |
1000 |
800 |
400 |
122 |
THREE-PHASE 415V TPN
|
| PART No. |
DIM A (mm) |
DIM B (mm) |
DIM C (mm) |
WEIGHT (kgs) |
| LM010/3 |
800 |
600 |
300 |
50 |
| LM015/3 |
800 |
600 |
300 |
70 |
| LM020/3 |
800 |
600 |
300 |
85 |
| LM030/3 |
800 |
600 |
300 |
100 |
| LM045/3 |
1000 |
800 |
400 |
150 |
| LM060/3 |
1000 |
800 |
400 |
185 |
| LM075/3 |
1800 |
600 |
600 |
235 |
| LM100/3 |
1800 |
600 |
600 |
255 |
| LM150/3 |
1800 |
600 |
600 |
330 |
PROTECTION (use MCB type 3 or HRC fuses
- preferably)
SINGLE PHASE
|
| PART No. |
KVA RATING |
PROTECTION REQUIRED |
| LM005/1 |
5 |
1 X 32A |
| LM010/1 |
10 |
1 X 63A |
| LM015/1 |
15 |
1 X 100A |
| LM020/1 |
20 |
1 X 125A |
| LM030/1 |
30 |
1 X 200A |
| LM040/1 |
40 |
1 X 250A |
| LM050/1 |
50 |
1 X 315A |
THREE PHASE
|
| PART No. |
KVA RATING |
PROTECTION REQUIRED |
| LM010/3 |
10 |
3 X 20A |
| LM015/3 |
15 |
3 X 32A |
| LM020/3 |
20 |
3 X 40A |
| LM030/3 |
30 |
3 X 63A |
| LM045/3 |
45 |
3 X 100A |
| LM060/3 |
60 |
3 X 125A |
| LM075/3 |
75 |
3 X 160A |
| LM100/3 |
100 |
3 X 200A |
| LM150/3 |
150 |
3 X 315A |
Click
here for Varmatic Lightmaster Trial Documentation [pdf file]
|